Product Information

JP Series 4

  • Basic Information
  • Product Lineup
  • Main Specifications

How to Read the Model Name

Example

Example

(1)
Type
Unit Type
U
Control Box
B
Stand-Alone Type
-
Head Type
H
(2)
Pressing Capacity
0.5kN
05
1kN
10
2kN
20
5kN
50
10kN
100
15kN
150
20kN
200
30kN
300
50kN
500
120kN
1200
(3)
Specs
Standard
-
Long Stroke Type
L
Clean Room Version
CL
Muting Version
M

*120kN Capacity Models are available in Unit Type only.

JP/JPH
-054
JP/JPH
-104
JP/JPH
-204
JP/JPH
-504(L)
JP/JPH
-1004(L)
JP/JPH
-1504(L)
Maximum Pressing Capacity(kN) 0.5 1 2 5 10 15
Ram Stroke(mm) 80 100
(L:150)
100
(L:150)
100
(L:150)
Maximum Speed(mm/sec)*1 166 100
Repeatability(mm)*2 ±0.005
Dimensions
W×D×H(mm)
(excluding cables and protrusions)
Stand-Alone Type Standard 520×567×750 520×585×875
(L:520×585×950)
Muting 520×567×783 520×585×917
(L:520×585×992)
520×580×917
(L:520x580x992)
Head Type 282×472×470 280×505×495
(L:280×505×570)
Weight(kg) Stand-Alone Type 100 160
(L:170)
Head Type 80 100
(L:110)
  JP - 2004
JPH-2004
JP - 3004
JPH-3004
JP - 5004
JPH-5004
JPU-12004
Maximum Pressing Capacity(kN) 20 30 50 120
Ram Stroke(mm) 200
Maximum Speed(mm/sec)*1 200[166] 300[200] 200[150]
Repeatability(mm)*2 ±0.005
Dimensions
W×D×H(mm)
(excluding cables and protrusions)
Unit Type - - 290×935×580
Stand-Alone Type Standard 520×813×1,236 560×985×1,315 -
Muting 560×985×1,350
Head Type 400×729×726 660×858×765 -
Control Box - - 550×550×230
Weight(kg) Unit Type - - 300
Stand-Alone Type 550 1,050 -
Head Type 360 650 -
Control Box - - 45

L…Long Stroke
M…Muting Version

*1 Maximum speed may vary depending upon conditions. The value in the parentheses is the initial speed setting.
*2 Position repeatability is not a guarantee of absolute precision.

  • These values are for standard models and may differ with specification modifications.
    Please contact us for details.
  • When configuring your facility for use with this product, be sure to perform your own risk assessment.

Common Specifications

Pressing Modes
Judgment Modes
Encoder Incremental Type (convertible to Absolute Type)
External Interface RSC-232C 1ch (9 pins, male type) COM1
External Input/Output I/O-SYS 17 Inputs/16 Outputs
Power Source Voltage 3 Phase・Single Phase 180~250V
However, with the 20kN and above types, 3 phase is standard.
Temperature 0~40°C
Relative Humidity 20~90% (Without condensation)
Ingress Protection (IP) Rating IP40
  • Specifications may be modified without prior notice to improve product quality.

Standard Accessories

Unit Type I/O-S Connector
I/O-SYS Connector (cable not included)
Short Connector for the Switch Box (cable not included)
Main Unit to Control Box Connector Cord (cord length: 3m)
Operation Manual (CD-ROM)
Stand-Alone Type I/O-S Connector
I/O-SYS Connector (cable not included)
Operation Manual (CD-ROM)
Head Type I/O-S Connector
I/O-SYS Connector (cable not included)
Switch Box (cord length: 2m)
Operation Manual (CD-ROM)

Optional Attachments

Common Specialized PC Software: JP TaS System (runs on Windows® 7/ Windows® 8.1/ Windows® 10 minimum required memory 512MB)
Ethernet Compatible
Load Cell Output
Encoder Output
I/O-SYS Cable(cord length: 2m, 3m, 5m)   
Unit Type Teaching Pendant
Main Unit to Control Box Connector Cord (cord length: 5m)*3
Switch Box (with connecting cable: 2m, 3m or 5m)
Monitor Box
Maintenance Box
Head Type Switch Box (with connecting cable: 3m or 5m )

*3 If you need a different length, please contact us.

Catalog and Diagram Download Contact Us