Product Information

JP Series 5 Stand-Alone Type (Flexible Model)

  • Basic Information
  • Product Lineup
  • Main Specificatons

How to Read the Model Code

Example

Example

(1)
Type
(2)
Maximum Load
(3)
Specifications
(4)
Rating
(5)
Model Type
(6)
Stroke
JPF 0055:0.5kN
0105:1kN
0205:2kN
0505:5kN
1005:10kN
1505:15kN
2005:20kN
3005:30kN
5005:50kN
N:Standard
N:Non-CE I:Incremental 080:80mm
100:100mm
200:200mm
  JPF-0055 JPF-0105 JPF-
0205
JPF-0505 JPF-1005 JPF-
1505
JPF-
2005
JPF-3005 JPF-5005
Maximum Pressing Capacity (kN) 0.5 1 2 5 10 15 20 30 50
Ram Stroke (mm) 80 100 200
Maximum Speed (mm/sec)*1 (T.B.D.) 280 (T.B.D.)
Position Repeatability(mm)*2 (T.B.D.) ±0.005 (T.B.D.)
Dimensions WxDxH(mm)*3 Press (T.B.D.) 325x505x947 (T.B.D.)
Switch Box (T.B.D.) 520x175x163 (T.B.D.)
Weight (kg)*3 Press (T.B.D.) 187 (T.B.D.)
Switch Box (T.B.D.) 4.8 (T.B.D.)
Encoder Incremental Type
Display Units Load unit: N, kgf, Lb  Length unit: mm, inch
Display Languages PC Software English, Japanese, Korean, Chinese (Simplified & Traditional)
Front Panel LCD English, Japanese, Korean, Chinese (Simplified & Traditional), Vietnamese, German, French, Spanish, Italian, Romanian, Czech
Drive and Control Method AC servomotor drive 32 bit CPU (dual core)
External Input/Output COM RS-232C 1ch
I/O-SYS 17 Inputs / 16 Outputs (Please choose NPN or PNP specifications when you place your order.)
LAN 10BASE-T/100BASE-TX
MEMORY For USB Memory Connection
・ Backup model setting data and teaching data
・ Save result data
・ Upgrade system software
Fieldbus
(optional)
CC-LINK, DeviceNet, PROFIBUS, CANopen, PROFINET, Ethernet/IP
*Specify at time of order
I/O-S For Safety Device Connection
Power Source Single Phase / 3 Phase AC200~240V ±10%
Work Environment Surrounding Temperature 0~40℃
Relative Humidity 20~90%(without condensation)
Ingress Protection Rating IP20

*1 Maximum speed may vary depending upon conditions.
*2 Position repeatability is not a guarantee of absolute position precision.
*3 Excluding cables and protrusions.

  • These values are for standard models and may differ with specification modifications.
    For more information, please visit our Catalog & Diagram Download Page or contact us directly.
  • When configuring your facility for use with this product, be sure to perform your own risk assessment.
  • Specifications may be modified without prior notice.

Standard Attachments

  • PC Software: JP5 Designer (Windows® 7, Windows® 8.1, Windows® 10, Microsoft Windows® Embedded Standard 7 compatible)
  • Operation Manual (CD-ROM)
  • Fieldbus Cover (for presses without an optional Fieldbus)
  • I/O-S Short Connector

Options

  • PC Software: JP TaSII System (Windows® 7, Windows® 8.1, Windows® 10, Microsoft Windows® Embedded Standard 7 compatible)

Catalog Diagram Download Contact Us